Phased array Ultrasonic Imaging system

PDS

Specifications

Phased Array UT System PAL3 (Pulser Receiver)
Number of Channels 128 ch
Parallel Focusing Channels 32 ch
Scan Display 0 ~ 5 µsec (5 nsec step)
Pulse Voltage 96V / 48V / 12V
Ultrasonic Flaw Detector HIS3 HF / LF (Evaluation Unit)
Number of Channels HF: 1 / LF: 2
Gate Tracking HF: IF / LF: IF, B, IF-B
DAC Function HF: × / LF : ○
Data Processing
OS Windows XP
A-Scan Display HIS3 & PC Monitor
B-Scan Display HIS3 & PC Monitor
C-Scan Display Real time display
3D-Display Arbitrary angle setting
DDF (Dynamic Depth Focusing) DDF data collection function
Display Color 256 color (gradation) , 2 color (gradation), binarization, color 16 contrast
Area Rate Display Histogram, specified color
Scanner (Three Axes Scanner)
Scanning Range X Axis: 500 mm (Standard) ~ 3500 mm
Y Axis: 400 mm (Standard) ~ 2500 mm
Z Axis: 300 mm (Standard) ~ 800 mm
θ Axis (1, 2): Manual operation / Automatic operation